This article covers:
InnoVint's mobile InnoApp is a powerful tool for recording analysis on the go: in the cellar, in the cave, and in the vineyard.
The app allows analysis data to be recorded and saved offline for upload to the cloud when you are back in range of a signal.
How to record Lot Composite or Individual Vessel Analysis
Via Quick Actions
Jump straight into analysis entry from the Quick Actions menu with either the "Record Analysis" or the "Record Sugar (Brix) & Temp" option.
Option 1. Record Analysis
This option allows you to record analysis against Lots (Lot Composite or Individual vessel) or Vineyard blocks.
- Select subject of analysis: Lot.
- To record lot analysis, select your lot and choose whether to record the analysis as Lot Composite or Individual vessel type analysis.
The Individual vessel type analysis selection will prompt a vessel selection if the lot is contained in more than one vessel. Otherwise, it will default to a single vessel.
- Select any existing analysis panel "+ Add Panel", or "Select Analysis."
If you choose "Select Analysis," commonly used analyses pre-populate the screen, but use the search icon to find any existing analysis type in InnoVint.
- Input analysis. Tap on the units to toggle through and change to any available units for the analysis type.
- Click Record to save analysis in the system.
Like everything else in this app, this works offline! Analysis results will be queued and saved until they can be uploaded to the cloud for access anywhere on the InnoVint platform.
Option 2. Record Sugar (Brix/Baume) & Temp
This option pre-populates the analysis type with your default sugar unit and temperature analysis.
- Select your lot and choose whether to record the analysis as Lot Composite or Individual vessel type analysis. The Individual vessel type analysis selection will prompt a vessel selection if the lot is contained in more than one vessel.
- Input your analysis results. Use the +/- icon to generate a negative result, and click on the units to toggle through and change available units on an analysis type.
- If you want to add an additional analysis type to your sugar/temps, just click on "Edit Analyses" to update the action.
- Click Record to save analysis in the system.
Record Analysis Via Lot Details or Vessel Details
Use the Record Action button from within either a Lot or Vessel Details page.
- Select Analysis from the Record Action menu.
- Select either Lot Composite or Individual vessel type analysis.
If you access the Analysis action via the Lot Details page, it will default to Lot Composite type analysis.
If you access the action via the Vessel Details page, it will default to Individual vessel type analysis, and default to the selected vessel.
In either case, you can choose to update selection as desired. - Select any existing analysis panel "+ Add Panel", or "Select Analysis."
If you choose "Select Analysis," some commonly used analyses pre-populate the screen, but use the search icon to find any existing analysis type in InnoVint. - Input your analysis results. Use the +/- icon to generate a negative result, and click on the units to toggle through and change available units on an analysis type.
- Click Record to save analysis in the system.
Record Analysis Via Work Order Tasks
- Tap into the analysis task details. You will see the analysis type (Lot Composite or Individual Vessel) and number of involved lots summarized at the top.
- Enter the results in the available fields. Tap on the units to toggle between available units.
- Complete task, and submit.
You cannot add analysis or lots via InnoApp.
Return to top
How to record Vineyard Block Analysis
Via Quick Actions
Jump straight into analysis entry from the Quick Actions menu using "Record Analysis".
This option allows you to record analysis against either Vineyard blocks or Lots.
- Select subject of analysis: Vineyard
- Select your vineyard and block. The block selection is dependent on the vineyard selection.
- Select any existing analysis panel, or ad hoc analysis. Commonly used analyses populate the screen if you choose "Select Analyses", but use the search icon to find any existing analysis type in InnoVint.
- Input analysis. Tap on the units to toggle through and change to any available units on an analysis type.
- Click Record to save analysis in the system.
Record Analysis Via Vineyard Details or Block Details
- Use the Record Action button from within either the Vineyard Details page, or the Block Details page.
- Select Analysis from the Record Action menu.
If you access the Analysis action via the Vineyard Details page, it will default to that Vineyard, and you still need to specify the block.
If you access the action via the Block Details page, it will automatically populate both Vineyard and Block.
In either case, you can choose to edit the selection with the blue pencil.
or - Select any existing analysis panel, or ad hoc analysis. Commonly used analyses populate the screen if you choose "Select Analyses", but use the search icon to find any existing analysis type in InnoVint.
- Click Record to save analysis in the system.
Like everything else in this app, all of this data entry works offline! Analysis results will be queued and saved until they can be uploaded to the cloud for access anywhere on the InnoVint platform.